应急灯安装接线示意图 Emergency light installs the wiring schematic drawing
所有应急灯输入线颜色定义为:
红色(棕色)...应急充电控制火线,黑色(兰色)...公共零线,绿色...正常照明控制火线
A:非持续式 应急灯接线方式(二线制):适合正常AC电源下不亮,断电后自动应急方式。
All emergency lights input line color definition is :Red(borwn)...the emergency charge controls the firing line.Black(bule color)...public zero curve.Green....Te normal illumination controls the firing line.
A:Must continuing-like fire prevention emergency light wiring way(two-wire system):Suits under the normal AC power source not to be bright.after power failure automatic emergency way.
B:持续式 应急灯接线方式(二线制):适合正常AC电源下常亮,断电后自动应急方式。
B:Continuing -like fire prevention emergency light wiring way(two-wire system):Suits under the normal AC pwoer source to be often bright,after powrefailure automatic emergency way.
C:可持续式 应急灯接线方式:适合正常AC电源下由K控制灯具亮灭,但不影响应急充电控制,断电后无论K处于何位,均不影响应急正常启动及工作。
C: Sustainable fire emergency light wiring way:Suits under the normal AC power source brightly to extinguish by the K control lamps and lanterns .But does not affect the emergency charge control.After the power failure regardless of K is in what.does not affect the emergency normal start and the work.

⑴群控(三线制)
⑴ group control (three-wire system)

⑵单控(三线制)
⑴ Accuse of only(three-wire system)
特别提示 Prompts specially
一:L不宜频繁关断;正常供电时由K控制灯具亮灭, 不得采取切断火线、零线电源,否则出现事故时, 应急灯具不能正常工作。
二: 应急灯使用镍镉电池组,出厂时电池处于 放空状态,使用前请充电24小时。
One:L should not be frequently shut off;Controlled the lamps and lanterns to kill bright by K while supplying power normal.Can't adopt and cut off battle line.Line zero power,while presenting the accident,the emergent lamps and lanterns can't work normally.
Two:The emergency light of fire control uses the nickle cadmium battery group,the battery is in putting the empty state when being dispatched from the factory.Please charge for 24 hours before using.
 